smartctl 6.6 2017-11-05 r4594 [armv7l-linux-4.19.66-v7l+] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Maxtor DiamondMax Plus 9
Device Model: Maxtor 6Y080M0
Serial Number: Y22025DC
Firmware Version: YAR51HW0
User Capacity: 81,964,302,336 bytes [81.9 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
Local Time is: Mon Oct 14 09:44:00 2019 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 30) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 37) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
3 Spin_Up_Time 0x0027 226 225 063 Pre-fail Always - 9742
4 Start_Stop_Count 0x0032 253 253 000 Old_age Always - 1235
5 Reallocated_Sector_Ct 0x0033 253 253 063 Pre-fail Always - 0
6 Read_Channel_Margin 0x0001 253 253 100 Pre-fail Offline - 0
7 Seek_Error_Rate 0x000a 253 252 000 Old_age Always - 0
8 Seek_Time_Performance 0x0027 252 239 187 Pre-fail Always - 57007
9 Power_On_Minutes 0x0032 230 230 000 Old_age Always - 428h+06m
10 Spin_Retry_Count 0x002b 253 252 157 Pre-fail Always - 0
11 Calibration_Retry_Count 0x002b 253 252 223 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 250 250 000 Old_age Always - 1225
192 Power-Off_Retract_Count 0x0032 253 253 000 Old_age Always - 0
193 Load_Cycle_Count 0x0032 253 253 000 Old_age Always - 0
194 Temperature_Celsius 0x0032 253 253 000 Old_age Always - 45
195 Hardware_ECC_Recovered 0x000a 253 252 000 Old_age Always - 1425
196 Reallocated_Event_Count 0x0008 253 253 000 Old_age Offline - 0
197 Current_Pending_Sector 0x0008 253 253 000 Old_age Offline - 0
198 Offline_Uncorrectable 0x0008 253 252 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0008 199 199 000 Old_age Offline - 0
200 Multi_Zone_Error_Rate 0x000a 253 252 000 Old_age Always - 0
201 Soft_Read_Error_Rate 0x000a 253 252 000 Old_age Always - 2
202 Data_Address_Mark_Errs 0x000a 253 252 000 Old_age Always - 0
203 Run_Out_Cancel 0x000b 253 252 180 Pre-fail Always - 1
204 Soft_ECC_Correction 0x000a 253 252 000 Old_age Always - 0
205 Thermal_Asperity_Rate 0x000a 253 252 000 Old_age Always - 0
207 Spin_High_Current 0x002a 253 252 000 Old_age Always - 0
208 Spin_Buzz 0x002a 253 252 000 Old_age Always - 0
209 Offline_Seek_Performnce 0x0024 253 253 000 Old_age Offline - 0
99 Unknown_Attribute 0x0004 253 253 000 Old_age Offline - 0
100 Unknown_Attribute 0x0004 253 253 000 Old_age Offline - 0
101 Unknown_Attribute 0x0004 253 253 000 Old_age Offline - 0
SMART Error Log Version: 1
Warning: ATA error count 267 inconsistent with error log pointer 5
ATA Error Count: 267 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 267 occurred at disk power-on lifetime: 7567 hours (315 days + 7 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 06 27 4a 0f e0 Error: UNC 6 sectors at LBA = 0x000f4a27 = 1002023
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 08 27 4a 0f e0 00 01:30:27.536 READ DMA EXT
25 03 08 3f 66 60 e0 00 01:30:27.520 READ DMA EXT
25 03 08 0f 18 17 e0 00 01:30:27.504 READ DMA EXT
25 03 40 47 78 19 e0 00 01:30:27.360 READ DMA EXT
25 03 40 5f a0 5f e0 00 01:30:27.344 READ DMA EXT
Error 266 occurred at disk power-on lifetime: 7566 hours (315 days + 6 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 37 70 49 0f e0 Error: UNC 55 sectors at LBA = 0x000f4970 = 1001840
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 f0 70 49 0f e0 00 00:06:25.504 READ DMA EXT
25 03 10 60 49 0f e0 00 00:06:25.504 READ DMA EXT
25 03 f0 70 48 0f e0 00 00:06:25.504 READ DMA EXT
25 03 10 60 48 0f e0 00 00:06:25.504 READ DMA EXT
25 03 f0 70 47 0f e0 00 00:06:25.504 READ DMA EXT
Error 265 occurred at disk power-on lifetime: 7566 hours (315 days + 6 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 06 27 4a 0f e0 Error: UNC 6 sectors at LBA = 0x000f4a27 = 1002023
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 d5 08 27 4a 0f e0 00 00:05:15.600 READ DMA EXT
25 d5 40 4f 7b 18 e0 00 00:05:15.584 READ DMA EXT
25 d5 08 cf f9 62 e0 00 00:05:15.584 READ DMA EXT
25 d5 08 27 22 a9 e0 00 00:05:15.584 READ DMA EXT
25 d5 08 d7 f9 62 e0 00 00:05:15.568 READ DMA EXT
Error 264 occurred at disk power-on lifetime: 7566 hours (315 days + 6 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 06 27 4a 0f e0 Error: UNC 6 sectors at LBA = 0x000f4a27 = 1002023
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 08 27 4a 0f e0 00 00:07:06.112 READ DMA EXT
25 03 60 77 00 60 e0 00 00:07:06.096 READ DMA EXT
25 03 08 57 1c 62 e0 00 00:07:06.080 READ DMA EXT
25 03 50 d7 1a 60 e0 00 00:07:06.080 READ DMA EXT
25 03 08 c7 1a 60 e0 00 00:07:06.080 READ DMA EXT
Error 263 occurred at disk power-on lifetime: 7566 hours (315 days + 6 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 77 20 4a 0f e0 Error: UNC 119 sectors at LBA = 0x000f4a20 = 1002016
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 80 20 4a 0f e0 00 00:06:17.216 READ DMA EXT
25 03 80 a0 49 0f e0 00 00:06:17.216 READ DMA EXT
25 03 80 20 49 0f e0 00 00:06:17.200 READ DMA EXT
25 03 40 e0 48 0f e0 00 00:06:17.184 READ DMA EXT
25 03 40 a0 48 0f e0 00 00:06:17.168 READ DMA EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 7568 -
# 2 Short offline Completed: read failure 60% 7566 1002025
# 3 Short offline Completed: read failure 60% 7565 1002025
# 4 Short offline Completed: read failure 60% 7565 1002025
# 5 Short offline Completed: read failure 60% 7564 1002025
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.