input for DIO1 which may be utilised for Rx timeouts. | input for DIO1 which may be utilised for Rx timeouts. | ||
- | On the XRobotix clone the LDO VREG has been replaced. VIN max is 6V rather than 16V and current max is 200mA instead of 600mA. | + | On the XRobotix clone the LDO VREG has been replaced. VIN max |
+ | is 6V rather than 16V and current max is 200mA instead of 600mA. | ||
+ | |||
+ | The board has been tested to work at 2.5V and will transmit at | ||
+ | this frequency even with the 16 MHz XTAL, however, the boot-loader | ||
+ | has a BOR setting of 2V7 which means it will continually reboot at | ||
+ | around 2.9V which is at the top of the BOR range for 2V7. The ATmega | ||
+ | and SX1276 can operate at 1.8V minimum. | ||
===Pinout=== | ===Pinout=== | ||
<wrap right> | <wrap right> | ||
Line 172: | Line 179: | ||
[[https:// | [[https:// | ||
+ | |||
+ | [[https:// |