Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
interfaces:mh-sensor [2016/01/21 13:18]
darron [Flying Fish MH Sensor]
interfaces:mh-sensor [2016/04/22 12:06]
darron [Flying Fish MH Sensor]
Line 1: Line 1:
 ==== Flying Fish MH Sensor ==== ==== Flying Fish MH Sensor ====
 <wrap right> <wrap right>
-{{:interfaces:mh-sensor.jpg?100}}+{{:interfaces:mh-sensor.jpg?200}} 
 +\\ \\ 
 +{{:interfaces:ivy.jpg?200}}
 </wrap> </wrap>
  
Line 7: Line 9:
 and a pot to give both an analogue and digital (threshold) output. and a pot to give both an analogue and digital (threshold) output.
  
-Various sensors configurations can be found which include an LDR, NTC thermistor, and +Various sensor configurations can be found which include an LDR, NTC thermistor,  
-two resistive water/moisture detectors+two resistive water/moisture detectors and more besides.
- +
-The moisture detectors utilise a 2 pin header which can allow us to reuse the +
-comparator board for any particular device we have available.+
  
 +The water/moisture detectors utilise a 2 pin header which can allow us to reuse the
 +comparator board for any particular device we have available. For example, the top picture
 +shows a flat style 10K thermistor along with the moisture detector kit.
  
 +Due to the circuit's simplicity, the digital output tends to oscillate when the
 +two inputs to the comparator have a similar magnitude.
 ===Schematic=== ===Schematic===
 +
 +This is a reversed engineered schematic, the capacitor values are unknown.
  
 {{:interfaces:mh-sensor.png?200}} {{:interfaces:mh-sensor.png?200}}
 +
 +===Moisture detector===
 +
 +After 3 months of use all I can say is this probe is mostly unusable, the
 +resistance value appears to be make little sense until at least you notice that
 +the probe is corroding. I have placed a second probe in the soil but this time
 +I have insulated the probe header (the other rusted) and now have the probe
 +against the inside edge of the pot rather than anywhere near the middle, maybe it will last longer...
 +